Engineering Metrology Question Bnak Objective

                 CENTRAL INSTITUTE OF PLASTICS ENGINEERING & TECHNOLOGY 

                                                       Question Bank 


1 MARK—QUESTION 

2 MARK ---QUESTION 

3 MARK --- QUESTION 

4/5 MARK ----QUESTION 

 COURSE : DPMT 

 SEMESTER: 3rd semester 

 SUBJECT : Engineering Metrology


                                                  -----------

1. _______________is the repeatability of a measuring process

2. B.H.N. Stands for ____________________

3. The two slip gauges in precision measurements are joined by _______________

4. _______________is the field of knowledge dealing with the problems of measurements

5. All the operations for the purpose of determining the values of the errors of a measuring instrument are called __________________

6. Spirit levels are used for measuring ________________________

7. The accuracy of micrometers, calipers, dial indicators can be checked by a _______________

8. CMM Stands for _____________________

9. Least count of Vernier caliper _______________

10. A clinometer is also known as ____________

11. RMS Stands for _________________

12. A _______________is used as a mechanical comparator

13. Interferometer are optical instruments used for measuring __________________

14. OPP stands for ___________________

15. The comparators are generally used for _______________measurements.

16. The toolmaker’s microscope is an _____________measurement machine.

17. “GO” and “NO GO” gauges must fulfill _____________Principle.

18. The comparator should at least be able to record variations of_______________.

19. Reed comparator is a _______________comparator.

20. _____________comparator has got a bold scale and large indicator pointer.

21. The scale in generally not uniform in _____________comparators.

22. Optical comparators has very high ________________

23. BIS Stands for __________________

24. For general use the measuring tip of a comparator should be

a) Flat                     b) Spherical                     c) Conical           d) Concave

25. ___________________is grade of slip gauge in suitable for workshop

a) Grade 0     b) Grade 00            c) Grade 2              d) Grade 1

26. Light source used in interferometer is

a) Helium          b) Hydrogen              c) krypton                 d) all the above

27. Which one of the following is the least accurate measuring device

a) Airgauge                  b) Optical projecter                 c) Micro Meter                    d) Steel scale

28. The least count of a micrometer

a) 0.5 mm             b ) 0.01mm               c) 0.02mm                d) 0.001mm

29. The combination set can be used to ______________

a) Check angular surface                      b) draw circles & arcs              c) scribe line              d) all of these

30. Millimeter scale in a micrometer is marked on

a) Barrel              b) Thimble             c) Anvil                  d) Ratchet

31. Optical flats are used in conjunction with

a) Angular Measurement             b) Surface parallelism           c ) surface profile              d) Interferometer measurements

32. _____________is used for measuring flatness

a) Profile projector                 b) CMM                  c) Tool makers microscope                 d) Interferometer

33. According to Indian standards, the slip gauges according to accuracy are graded into following categories

a) 2           b) 3                c) 4                d) 6

34. Which of the following can be used to scribe line parallel to the edges of a part

a) Vernier caliper          b) Screw gauge            c) Divider                     d) Hermaphrodite caliper

35. A feeler gauge is used to check

a) Radius       b) Screw pitch            c) Surface roughness                  d) Thickness of clearances

36. Optical flats are made of

a) Quartz               b) Glass              c) Plastic                 d) silicon

37. A sine bar is specified by

a) Its total length                b) the centre distance between the two rollers

c) The size of rollers            d) Weight of sine bar

38. The number of slip gauges in set are

a) 87                  b) 45                         c) 103           d) 31

39. Profile of a gear tooth can be checked by

a) Sinebar                b) Bench micrometer         c ) Optical projector          d) Slip gauge

40. The basic unit in angular measurement is

a) Degree       b) Minute                      c) Second       d) Right angle

41. Which of the following is not provided on Combination set

a) Centre head                 b) Protractor head              c) Vernier scale               d) Spirit level

42. A comparator for its working depends on

a) Accurately calibrated scale                   b) Comparison with standard such as slip gauges

c) Accurately micrometer gauge                          d) optical devices

43. Surface roughness on a drawing is represented by

a) Triangle              b) Circles                         c) Squares                d) rectangle

44. One micron is equal to

a) 1mm             b) 0.1mm               c) 0.01mm            d) 0.001mm

45. Which of the following is not the angle measuring device?

a) Angle plate       b) Sine bar                        c) Bevel protractor      d) Angle Gauge

46. Straight edges are used to measure

a) Parallelism          b) Flatness              c) Circularity              d) Straight length of parts

47. Bevel protractor is used for

a) Angular measurements               b) Linear measurements

c) height measurements          d) flatness measurement

48. Autocollimator is used for

a) Parallelism measurement            b) Straightness measurement

c) flatness measurement                    d) angular measurement

49. Angle dekkor is another type of

a) Auto collimator           b) Optical Square        c) Clinometer             d) angle gauge

50. The following is not used to measure angles

a) Bevel protractor             b) Calibrated Levels            c) Clinometers                 d) Optical flats

51. “GO” and “NO GO” gauge is a type of

a) Plug gauge             b) Slip gauge                   c) Ring gauge                 d) Limit gauge

52. The following is not a type of comparator

a) Electrical                   b) Pneumatic                c) Optical                 d) Hydraulic

53. Optical gauge works on the principle of

a) Reflection                     b) Refraction                    c) Interference of light rays                   d) polarization

54. The degree of closeness of the measured value of a certain quantity with its true value is known as

a) accuracy                  b) precisionn                c) standard                   d) sensitivity

55. Error of Measurement

a) True Value – Measured value                 b) Precision – True value

c) Measured value – Precision                d) none of the above.

56. The following is an internationally recognized and accepted unit system

a) MKS             b) FPS                   c) SI                  d ) All of the above.

57. The following is a line standard of measurement

a) Measuring tape                 b) slip gauge                    c) micrometer                   d) End bars

58. The following is used to check the diameters of holes

a) Plug gauge                  b) ring gauge                 c) Slip gauge                   d) Standard screw pitch gauge

59. Which of the following is not a type of direct measuring measurement?

a) Micrometer            b) Vernier caliper               c) Divider                  d) all the above

60. Johansson mickrocator is a type of

a) Mechanical optical comparator                b) Mechanical comparator

(c) Optical comparator               d) Electrical comparator

61. Engineers parallels are available

a) Solid type       b) Box type            c) Adjustable type             d) all of the above.

62. Combination set the squaring and scale cube used for

a) Height measurement              b) Depth measurement        c) Both of above       d) none of all

63. Which type of comparator changes its magnification, when distance between cross strip hinge and knife edge is varied?

a) Johnson mickrocator         b) solex pneumatic comparator           c) projector comparator                          d) sigma comparator

64. Which of the following instrument is most accurate

a) Mechanical comparator   b) optical projector           c) slip gauge              d) vertical caliper

65. Which of the following errors are regularly repetitive in nature?

a) Systematic errors       b) Random errors           c) Illegitimate errors             d) Controllable errors

66. A surface gauge is used for

a) Leveling the surface plate         b) Checking the surface finish

c) Laying out the work accurately            d) Finding the depth of the surface

67. External taper can be accurately measured with the help of

a) Sine bar and slip gauges            b) Dividing head               c) Combination set            d) Clinometer

68. Standards to be used for reference purpose in Laboratories and workshops are referred to as

a) Primary standards              b) Secondary standards               c) Tertiary standards       d) Working standards

69. The following type of gauge has gauging sections combined on one end

a) Combination gauge             b) Limit gauge                 c) Fixed gauge            d) Progressive gauge

70. Clinometer is related with

a) Engineers parallels               b) Spirit level               c) Angle Gauges          d) sine bar

71. Taylor’s principle is concerned with

a) Pneumatic comparators          b) Gauging measurements

c) Angular measurements                      d) Roundness measurements

72. Clinometer is used for

a) Angular measurement        b) Linear measurement

c) Bore measurement                    d) Level of flat surfaces.

73. Measuring accuracy of Vernier bevel protractor

a) 5 Minutes               b) 2 Minutes                   c) 10 Minutes                 d) 1 Minute

74. Measuring accuracy of sine bar

a) 2 seconds                  b) 3 seconds              c) 5 seconds                   d) 1 second

75. A work is usually required to be held in a vertical position for laying out for this purpose it is clamped to

a) Surface Plat              b) an angle Plate                  c ) a V Block               d) Engineers square

76. Element of the indicating device carrying the scale is called

a) dial                 b) housing                  c) Index                    d) Frame

77. The term traceability in engineering metrology is concerned with

a) Measuring Machines                       b) Optical Instruments                        c) Standards                 d) Limits and fits

78. Sine bar is not preferred for measuring angle more than 45 degree – say True or False

79. The various roughness grade number N1 to N24 in 5 groups are specified as under by BIS – Say True or False

80. As per Taylor’s principle gauges are made to check the minimum metal conditions say True or False

81. V-block is used in the workshop to check the dimension of oval job – say True or False

82. V block also be used to support rectangular components at 45 ° to the datum surface say True of false

83. Universal surface gauge instrument used in non – precision measurements. say True of false

84. Feeler gauges are used to measure the width of the gap between two parallel flat faces say True of false

85. Screw pitch gauge is used for measuring (or) checking the pitch of internal threaded component only. Say True of false

86. In type A Vernier caliper the jaws are provided on both sides for external & internal measurements

Say True or false

87. Error is the difference between the indicated and actual value of the measured say True or false

88. Slip gauges are square blocks say True or false

89. Universal bevel protractor, the blade cannot be rotated to measure any angles say True or false

90. Least count of Vernier bevel protractor is 5 minutes say True or false

91. Autocollimator is used for the measurement of small angular differences say True or false

92. Sigma comparator is a type of mechanical comparator say True or False

93. Mechanical comparators are compact and easy to handle. say True or False

94. Slip gauges are rectangular block say True or False

95. Engineers parallel available in three types. say True or False

96. A spirit level consists of a sealed glass tube say True or False

97. Sine bar based on the laws of Trigonometry say True of False

98. Solex Pneumatic Comparator has very high magnification capacity - say True of False

99. CMM is used for checking and measuring various gauges and fixtures- say True of False

100. Which of these is not a type of micrometer

a) outside b) inside c) height d) depth

101. A ___________ consists of a hardened, precision ground body with two precision ground cylinders

fixed at the ends.

a) vernier caliper b) micrometer c) spirit level d) sine bar

102. Sine bar is used in conjunction with slip gauges for precise ______ measurement

a) height b) angular c) distance d) depth

Post a Comment

0 Comments
* Please Don't Spam Here. All the Comments are Reviewed by Admin.